1675 Paintwork

The painted timber here was discovered hidden behind a partition. It is a rare survival. Monitoring relative humidity levels will inform how to control the heating to prevent the paint flaking from the doors and panelling.

image

Tapestry (really embroidery)

This modern but valuable artwork was coming to visit. Integrated Pest Management was in place and had identified the presence of carpet beetle larvae. The room was fogged with Constrain, a conservation grade insecticide, and the heating was turned down. Both actions will seriously deter pests from approaching the textiles. Sticky pest traps will confirm the efficacy of the preventive works.

image

Slaters & Slater Spiders

This insect trap has caught some slaters some slater spiders. This is a sign of a reasonably damp environment not necessarily a problem as neither slaters all these spiders will damaged the textiles in this historic building. If we had clothes moths, carpet beetles or woodworm then there would be more cause for concern.

image

Church Heating Trial

We have put in a temporary electric heating system to see if we can control humidity levels. Three electric heaters are enough to keep humidity levels to a level where mould woodworm and similar problems won’t occur. The Hanwell humidistat controls all three radiators using temporary cables. Perhaps one day the  victorian heating system will be reinstalled.

image

New Display Case

This case is protecting archaeological objects from potentially high relative humidity. We’re looking to see if the silica gel is effective enough in it’s own or whether the heating in the museum needs to be adjusted. The airtightness of the case needs to be assessed, as does the amount and type of silica gel. 

image

Background Church Heating

This church stays closed all winter but can’t just be left without heating. Equally it’s Victorian heating system is no longer working. An effective but temporary fix is to install a few electric heaters on humidistat control. This has effectively improved conditions in the church without much effort or expense. Data loggers record how effective it is.

image

Lighthouse

This is now a museum and the lighthouse keeper’s accommodation is now a 1970’s time capsule. It can’t just be left to decay so a humidistat controlled radiator has been installed. This also keeps the place a little warmer than normal during the  shoulder months as there is a temperature boost button on the controls. It gets quite cosy but the telly doesn’t work any more.

image

Fog Horn Engines

These old diesel engines are still run occasionally as part of the visitor experience. Most of the time though they just sit in the room with a bit of conservation heating to keep them condensation free and to keep the more delicate objects on the room in good condition.

image

Classic Car Conservation

This 1955 Daimler came into care at the same time as the house and garden. It’s being keep in a protective bubble known as a CARCOON that protects it against dust and changes in relative humidity. It’s a good move from a conservation point of view and a good talking point. There’s a little bit more work to do though in optimising relative humidity levels.

image

Wet Stone

A leak in one radiator has meant that all the heating in this Hebridian church has had to be switched off. This has allowed the stone to cool down to such an extent that condensation forms in the coldest areas and runs down the walls. A return to background heating will fix the worst of this.

image

Unusual Conservation Heating

This little museum is suffering from high relative humidity meaning that some of the collection has had to be taken off display.  We installed two electric radiators and a blade-less fan to push the warm air around silently and efficiently. A humidistat controls the radiators. Environmental monitoring will confirm whether we have solved the problem.

image

Monitoring System Upgrade

a Meaco environmental monitoring system has been faithfully recording data in this exhibition since 2007. It still works but the computer running the system is getting slower and slower to the point where it needs to be changed. This is quite involved as it means a new computer, update of Meaco software and update of Windows from XP to 8, all the time ensuring that no data is lost and that the older telemetry sensors work on the new computer.

image